Skip to main content
All CollectionsKnowledge share from RuptelaSWTrust Track
Configuration of CANBUS inputs in Object Settings
Configuration of CANBUS inputs in Object Settings
Updated over 10 months ago

How to configure inputs from CANBUS:

  1. In Trust Track admin panel go to [objects] window;

  2. Find desired object by using available filters, this include Object ID, company name, object name, IMEI number etc.;

  3. Click [view/edit] for object you want to configure:
    ​

    mceclip0.png
  4. After opening object editing window, scroll down untill you see Custom inputs field;

  5. For the most common parameters mentioned above, custom inputs 13-16 are ussualy used, enable them;

  6. Select input parameters as shown in the picture;

  7. Select [Linear] option inf "Function column;

  8. Enter desired MIN and MAX values for each parameter. This can be used to filter error, zero or any other unwanted vales:

    blobid4.png
  9. Scroll down the page and click [Save];

  10. Scroll back up and set required constants for each parameter. Click [SET], a new table will pop-up.
    ​

    - Left column [X] is intended for Digital values which are sent from the device.

    - Right column [Y] is for coresponding values which are shown depending on received digital value

  11. If variation of parameter is linear, two rows are enough. In variation is non-linear, you can ad as many rows as you need by clicking [Add row];

  12. After required constants are entered click [Save] in the table. Constants for most commonly used parameters are provided in the table below:

    blobid5.png

Example of raw data excel report with raw and recalculated inputs:

mceclip1.png
Did this answer your question?