Explanation:
Output activation logic allows you to implement triggers that act upon a specific output based on external signals. These triggers use voltage levels (for analog inputs) or digital states (for digital inputs) as a reference to initiate an action.
Guidelines:
1. In the Advanced Configurator, navigate to "IO events" to access the input and output configuration settings.
2. To configure an analog input, define the voltage threshold in the "Level" field. In the "Average" field, set the duration required to confirm the activation. Set "Event on" to "Hysteresis"; within this function, select "On both" to receive alerts for both activation and deactivation, or select "On Rising" if you only wish to receive an alert upon the initial active state. Set "Priority" to "high".
3. Configure the digital input to detect state changes. In the "Debounce" field, set the time required to confirm the activation. Set "Event on" to "Change" to detect both activation and deactivation of the digital input. Set "Priority" to "high".
4. Configure the digital output as "LED".
5. Navigate to "Activation conditions" to configure the activation logic.
6. To activate the output via analog input, enable the "Activation by AIN" function. In "Output channel", link the analog input to the digital output by selecting "LED". In "Voltage limit", enter the voltage threshold that will trigger the logic. In "Input", select the previously configured analog input (e.g., AIN1). Finally, set the duration the output should remain active by selecting "Deactivation timeout" and entering the desired time in seconds.
7. To activate the output via digital input, enable the "Activation by DIN" function. In "Output channel", select the "LED" output. In "DIN level", set the activation state (e.g., "High"). In "Input", select the previously configured digital input (e.g., DIN1). Finally, set the duration the output should remain active by selecting "Deactivation timeout" and entering the desired time in seconds.
Expected outcome: Testing the analog input results in immediate output activation when a value exceeding 10,000 millivolts is detected; the output remains active for 15 seconds before deactivating. This same behavior is observed when configuring the digital input.
Tools required
Name: | Link: |
Advanced configurator |
Related Documentation
Name: | Link: |
Digital output configuration |
Keywords:
Plug5, Eco5, Smart5, HCV5, Pro5, LCV5, Pro5S, HCV5 lite, Pro5 lite, Trace5, Advanced configurator, analog input, digital output, activation conditions.