Description:
How to set input constants on LCM for Trailers IO:
-
Trailers Brake cylinder pressure third axle (right and left)
-
Trailers Brake cylinder pressure second axle (right and left)
-
Trailers Brake cylinder pressure first axle (right and left)
-
Trailers Axle load sum
-
Trailers Pneumatic supply pressure
Required information:
Information needed to perform the task (plus who needs to provide it)
Object ID, imei or serial number | Client |
Required inputs | Client |
Recommended tools:
link all the apps needed to perform the task
Application | Download link |
Admin panel (LCM) | Admin panel login URL |
Steps:
Some IO parameters are already calculated in the back end and in TT raw data we have calculated value. In this case, these trailers IO are already braked and calculated
- Trailers Brake cylinder pressure third axle - is already split up and calculated on the TT (back end) side, LCM we are setting the value as it coming.
- Trailers Pneumatic supply pressure - is already split up and calculated on the TT (back end) side, LCM we are setting the value as it coming.
- Trailers Axle load sum - also already calculated on TT and the coming value is provided in Kg. so to have tons setting would be p1/1000
For input observation in TT, we select required custom inputs, select source, and such constants:
More information on IO can be found: FMIO parameter list